To ensure structural safety, understanding the behavior of foundations on collapsible soils under moisture variation is crucial. This study evaluates the performance of isolated footings installed in collapsible soil from Uberlândia (MG) under two scenarios: directly flooded without preloading, and preloaded before flooding. Both footings were subjected to slow static load tests and analyzed through three-dimensional numerical modeling using RS3 software. The results demonstrated a significant reduction in bearing capacity when flooding occurred prior to loading (up to 64%), compared to a 24% reduction when preloading was applied before inundation. The stress–settlement curves further revealed that preloading led to stiffer soil response and higher bearing capacity, with a 53% increase at 25 mm settlement compared to the non-preloaded case. These findings highlight the effectiveness of preloading in improving the performance of shallow foundations on collapsible soils under saturated conditions.